Structure factors have been supplied for datablock(s) I
No syntax errors found. CIF dictionaryStructure factor report
Please wait while processing .... Interpreting this report
| Bond precision: | C-C = 0.0036 A | Wavelength=0.71073 |
| Cell: | a=17.8518(11) | b=10.2950(6) | c=18.4542(10) |
| alpha=90 | beta=108.865(3) | gamma=90 | |
| Temperature: | 100 K |
| Calculated | Reported | |
| Volume | 3209.4(3) | 3209.4(3) |
| Space group | P 21/c | P 21/c |
| Hall group | -P 2ybc | -P 2ybc |
| Moiety formula | C30 H30 N6 Ni, 1.814(B F4), 0.188(Cl) | C30 H30 N6 Ni, 1.823(B F4), 0.181(Cl) |
| Sum formula | C30 H30 B1.81 Cl0.19 F7.26 N6 Ni | C30 H30 B1.81 Cl0.19 F7.26 N6 Ni |
| Mr | 697.43 | 697.47 |
| Dx,g cm-3 | 1.443 | 1.443 |
| Z | 4 | 4 |
| Mu (mm-1) | 0.694 | 0.693 |
| F000 | 1430.3 | 1430.0 |
| F000' | 1432.49 | |
| h,k,lmax | 23,13,24 | 23,13,24 |
| Nref | 8018 | 7959 |
| Tmin,Tmax | 0.812,0.933 | 0.819,0.934 |
| Tmin' | 0.812 |
| Correction method= # Reported T Limits: Tmin=0.819 Tmax=0.934 AbsCorr = MULTI-SCAN |
| Data completeness= 0.993 | Theta(max)= 28.340 |
| R(reflections)= 0.0464( 6403) | wR2(reflections)= 0.1324( 7959) |
| S = 1.034 | Npar= 506 |
The following ALERTS were generated. Each ALERT has the format
test-name_ALERT_alert-type_alert-level.
Click on the hyperlinks for more details of the test.
Alert level C
PLAT077_ALERT_4_C Unitcell contains non-integer number of atoms .. Please Check
PLAT911_ALERT_3_C Missing # FCF Refl Between THmin & STh/L= 0.600 15 Report
PLAT918_ALERT_3_C Reflection(s) with I(obs) much Smaller I(calc) . 1 Check
PLAT978_ALERT_2_C Number C-C Bonds with Positive Residual Density 0 Note
Alert level G
FORMU01_ALERT_1_G There is a discrepancy between the atom counts in the
_chemical_formula_sum and _chemical_formula_moiety. This is
usually due to the moiety formula being in the wrong format.
Atom count from _chemical_formula_sum: C30 H30 B1.81 Cl0.19 F7.26
Atom count from _chemical_formula_moiety:C30 H30 B1.823 Cl0.181 F7.2
PLAT002_ALERT_2_G Number of Distance or Angle Restraints on AtSite 24 Note
PLAT042_ALERT_1_G Calc. and Reported MoietyFormula Strings Differ Please Check
PLAT066_ALERT_1_G Predicted and Reported Tmin&Tmax Range Identical ? Check
PLAT068_ALERT_1_G Reported F000 Differs from Calcd (or Missing)... Please Check
PLAT171_ALERT_4_G The CIF-Embedded .res File Contains EADP Records 3 Report
PLAT175_ALERT_4_G The CIF-Embedded .res File Contains SAME Records 4 Report
PLAT244_ALERT_4_G Low 'Solvent' Ueq as Compared to Neighbors of B1 Check
PLAT301_ALERT_3_G Main Residue Disorder ............ Percentage = 8 Note
PLAT302_ALERT_4_G Anion/Solvent Disorder ............ Percentage = 46 Note
PLAT304_ALERT_4_G Non-Integer Number of Atoms ( 1.59) in Resd. # 3 Check
And 3 other PLAT304 Alerts
PLAT304_ALERT_4_G Non-Integer Number of Atoms ( 2.49) in Resd. # 4 Check
PLAT304_ALERT_4_G Non-Integer Number of Atoms ( 0.13) in Resd. # 5 Check
PLAT304_ALERT_4_G Non-Integer Number of Atoms ( 0.06) in Resd. # 6 Check
PLAT432_ALERT_2_G Short Inter X...Y Contact Cl2 .. C20 .. 2.98 Ang.
PLAT860_ALERT_3_G Number of Least-Squares Restraints ............. 40 Note
PLAT910_ALERT_3_G Missing # of FCF Reflection(s) Below Theta(Min) 1 Note
PLAT912_ALERT_4_G Missing # of FCF Reflections Above STh/L= 0.600 37 Note
PLAT913_ALERT_3_G Missing # of Very Strong Reflections in FCF .... 1 Note
PLAT933_ALERT_2_G Number of OMIT records in Embedded RES ......... 12 Note
0 ALERT level A = Most likely a serious problem - resolve or explain
0 ALERT level B = A potentially serious problem, consider carefully
4 ALERT level C = Check. Ensure it is not caused by an omission or oversight
20 ALERT level G = General information/check it is not something unexpected
4 ALERT type 1 CIF construction/syntax error, inconsistent or missing data
4 ALERT type 2 Indicator that the structure model may be wrong or deficient
6 ALERT type 3 Indicator that the structure quality may be low
10 ALERT type 4 Improvement, methodology, query or suggestion
0 ALERT type 5 Informative message, check
|
Publication of your CIF
You should attempt to resolve as many as possible of the alerts in all categories. Often the minor alerts point to easily fixed oversights, errors and omissions in your CIF or refinement strategy, so attention to these fine details can be worthwhile. In order to resolve some of the more serious problems it may be necessary to carry out additional measurements or structure refinements. However, the nature of your study may justify the reported deviations from journal submission requirements and the more serious of these should be commented upon in the discussion or experimental section of a paper or in the "special_details" fields of the CIF. checkCIF was carefully designed to identify outliers and unusual parameters, but every test has its limitations and alerts that are not important in a particular case may appear. Conversely, the absence of alerts does not guarantee there are no aspects of the results needing attention. It is up to the individual to critically assess their own results and, if necessary, seek expert advice. If you wish to submit your CIF for publication in Acta Crystallographica Section C or E, you should upload your CIF via the web. If you wish to submit your CIF for publication in IUCrData you should upload your CIF via the web. If your CIF is to form part of a submission to another IUCr journal, you will be asked, either during electronic submission or by the Co-editor handling your paper, to upload your CIF via our web site. |
| Datablock I - ellipsoid plot |
|